21.8 Tomographic Images, CAT Scans (Computed Axial Tomography)

Chapter Contents (Back)
Tomography. CT. CAT.
See also Tomographic Image Reconstruction, Radon Transform.
See also Backprojection in Tomographic Image Reconstruction.

The Nobel Prize in Physiology or Medicine 1979/TR>, 1979 'https://www.nobelprize.org/prizes/medicine/1979/perspectives/',
Allan Cormack published the original theory in 1963-4 of the mathematics of combining multiple X-Ray measurements (
See also Representation of a Function by Its Line Integrals with Some Radiological Applications. ). Godfrey Hounsfield, built the first CT scanner in 1971. They shared the 1979 Nobel Prize.

Kobashi, M., Shapiro, L.G.,
Knowledge-Based Organ Identification from CT Images,
PR(28), No. 4, April 1995, pp. 475-491.
Elsevier DOI BibRef 9504
And:
Knowledge-Based Matching for 3D Radiotherapy Planning,
ICPR92(I:293-296).
IEEE DOI BibRef

Cash, D.M., Miga, M.I., Sinha, T.K., Galloway, R.L., Chapman, W.C.,
Compensating for Intraoperative Soft-Tissue Deformations Using Incomplete Surface Data and Finite Elements,
MedImg(24), No. 11, November 2005, pp. 1479-1491.
IEEE DOI 0512
BibRef

Brown, M.S., McNitt-Gray, M.F., Mankovich, N.J., Goldin, J.G., Hiller, J., Wilson, L.S., Aberle, D.R.,
Method for Segmenting Chest CT Image Data Using an Anatomical Model: Preliminary-Results,
MedImg(16), No. 6, December 1997, pp. 828-839.
IEEE Top Reference. 9803
BibRef

Kong, T.Y., Herman, G.T.,
On Which Grids Can Tomographic Equivalence of Binary Pictures Be Characterized in Terms of Elementary Switching Operations,
IJIST(9), No. 2-3, 1998, pp. 118-125. 9805
BibRef

Yang, G.Z., Hansell, D.M.,
CT Image-Enhancement with Wavelet Analysis for the Detection of Small Airways Disease,
MedImg(16), No. 6, December 1997, pp. 953-961.
IEEE Top Reference. 9803
BibRef

Frakt, A.B., Karl, W.C., Willsky, A.S.,
A Multiscale Hypothesis Testing Approach to Anomaly Detection and Localization from Noisy Tomographic Data,
IP(7), No. 6, June 1998, pp. 825-837.
IEEE DOI 9806
BibRef
Earlier: A1, A3, A2:
Multiscale hypothesis testing with application to anomaly characterization from tomographic projections,
ICIP96(II: 705-708).
IEEE DOI 9610
BibRef

Fuchs, T.O.J., Kachelriess, M., Kalender, W.A.,
Direct comparison of a xenon and a solid-state CT detector system: measurements under working conditions,
MedImg(19), No. 9, September 2000, pp. 941-948.
IEEE Top Reference. 0110
BibRef

Hsieh, J.[Jiang], Gurmen, O.E., King, K.F.,
Investigation of a solid-state detector for advanced computed tomography,
MedImg(19), No. 9, September 2000, pp. 930-940.
IEEE Top Reference. 0110
BibRef

Hsieh, J.,
A 2X interpolative algorithm for helical computed tomography,
ICIP95(II: 464-467).
IEEE DOI 9510
BibRef

Boag, A., Bresler, Y., Michielssen, E.,
A Multilevel Domain Decomposition Algorithm for Fast O(N2 log N) Reprojection of Tomographic Images,
IP(9), No. 9, September 2000, pp. 1573-1582.
IEEE DOI 0008
BibRef
Earlier: ICIP00(Vol II: 633-636).
IEEE DOI 0008
BibRef

Pardo, X.M., Carreira, M.J., Mosquera, A., Cabello, D.,
A snake for CT image segmentation integrating region and edge information,
IVC(19), No. 7, May 2001, pp. 461-475.
Elsevier DOI 0104
BibRef

Zeng, G.S.L.[Geng-Sheng L.], You, J.S.[Jiang-Sjemg], Huang, Q.[Qiu], Gullberg, G.T.[Grant T.],
Two finite inverse Hilbert transform formulae for region-of-interest tomography,
IJIST(17), No. 4, 2007, pp. 219-223.
DOI Link 0712
BibRef

Snyder, D.L., O'Sullivan, J.A., Whiting, B.R., Murphy, R.J., Benac, J., Cataldo, J.A., Politte, D.G., Williamson, J.F.,
Deblurring subject to nonnegativity constraints when known functions are present with application to object-constrained computerized tomography,
MedImg(20), No. 10, October 2001, pp. 1009-1017.
IEEE Top Reference. 0111
BibRef

Salem, K.A., Szymanski-Exner, A., Lazebnik, R.S., Breen, M.S., Gao, J.M.[Jin-Ming], Wilson, D.L.,
X-ray computed tomography methods for in vivo evaluation of local drug release systems,
MedImg(21), No. 10, October 2002, pp. 1310-1316.
IEEE Top Reference. 0301
BibRef

Carney, P.S.[P. Scott], Schotland, J.C.[John C.],
Theory of total-internal-reflection tomography,
JOSA-A(20), No. 3, March 2003, pp. 542-547.
WWW Link. 0304
BibRef

Liseno, A.[Angelo], Pierri, R.[Rocco],
Imaging of voids by means of a physical-optics-based shape-reconstruction algorithm,
JOSA-A(21), No. 6, June 2004, pp. 968-974.
WWW Link. 0409
BibRef

Bartesaghi, A., Sapiro, G., Subramaniam, S.,
An Energy-Based Three-Dimensional Segmentation Approach for the Quantitative Interpretation of Electron Tomograms,
IP(14), No. 9, September 2005, pp. 1314-1323.
IEEE DOI 0508
BibRef

Krishnamurthi, G., Stantz, K.M., Steinmetz, R., Gattone, V.H., Cao, M.[Minsong], Hutchins, G.D., Liang, Y.[Yun],
Functional imaging in small animals using X-ray computed Tomography: Study of physiologic measurement reproducibility,
MedImg(24), No. 7, July 2005, pp. 832-843.
IEEE DOI 0508
BibRef

Fillatre, L.[Lionel], Nikiforov, I.[Igor],
A Statistical Detection of an Anomaly from a Few Noisy Tomographic Projections,
JASP(2005), No. 14, 2005, pp. 2215-2228.
WWW Link. 0603
BibRef

Fillatre, L.[Lionel], Nikiforov, I.[Igor], Retraint, F.,
epsilon-Optimal Non-Bayesian Anomaly Detection for Parametric Tomography,
IP(17), No. 11, November 2008, pp. 1-15.
IEEE DOI 0810
BibRef

Donath, T.[Tilman], Beckmann, F.[Felix], Schreyer, A.[Andreas],
Automated determination of the center of rotation in tomography data,
JOSA-A(23), No. 5, May 2006, pp. 1048-1057.
WWW Link. 0610
BibRef

Serlie, I.W.O., Vos, F.M., Truyen, R., Post, F.H., van Vliet, L.J.,
Classifying CT Image Data Into Material Fractions by a Scale and Rotation Invariant Edge Model,
IP(16), No. 12, December 2007, pp. 2891-2904.
IEEE DOI 0711
BibRef

Batenburg, K.J.[K. Joost], Sijbers, J.[Jan],
Optimal Threshold Selection for Tomogram Segmentation by Projection Distance Minimization,
MedImg(28), No. 5, May 2009, pp. 676-686.
IEEE DOI 0905
BibRef
Earlier:
Selection of Local Thresholds for Tomogram Segmentation by Projection Distance Minimization,
DGCI08(xx-yy).
Springer DOI 0804
BibRef
Earlier:
Optimal Threshold Selection for Tomogram Segmentation by Reprojection of the Reconstructed Image,
CAIP07(563-570).
Springer DOI 0708
BibRef

Batenburg, K.J.[K. Joost], Sijbers, J.[Jan],
Adaptive thresholding of tomograms by projection distance minimization,
PR(42), No. 10, October 2009, pp. 2297-2305.
Elsevier DOI 0906
Local thresholding; Adaptive thresholding; Tomography; Projections; PDM; Segmentation BibRef

van Aarle, W., Batenburg, K.J.[K. Joost], Sijbers, J.[Jan],
Optimal Threshold Selection for Segmentation of Dense Homogeneous Objects in Tomographic Reconstructions,
MedImg(30), No. 4, April 2011, pp. 980-989.
IEEE DOI 1104
BibRef
Earlier: A2, A1, A3:
Grey Level Estimation for Discrete Tomography,
DGCI09(517-529).
Springer DOI 0909
BibRef
Earlier: A1, A2, A3:
Threshold Selection for Segmentation of Dense Objects in Tomograms,
ISVC08(I: 700-709).
Springer DOI 0812
BibRef

Batenburg, K.J.[K. Joost], van Aarle, W., Sijbers, J.[Jan],
A semi-automatic algorithm for grey level estimation in tomography,
PRL(32), No. 9, 1 July 2011, pp. 1395-1405.
Elsevier DOI 1101
Discrete tomography; Grey level estimation; Segmentation
See also Automatic Parameter Estimation for the Discrete Algebraic Reconstruction Technique (DART). BibRef

Fortes, W.[Wagner], Batenburg, K.J.[K. Joost],
A Method for Feature Detection in Binary Tomography,
DGCI13(372-382).
Springer DOI 1304
BibRef
And:
Error Bounds on the Reconstruction of Binary Images from Low Resolution Scans,
CAIP11(I: 152-160).
Springer DOI 1109
BibRef

Batenburg, K.J.[K. Joost], Fortes, W.[Wagner], Hajdu, L.[Lajos], Tijdeman, R.[Robert],
Bounds on the Difference between Reconstructions in Binary Tomography,
DGCI11(369-380).
Springer DOI 1104
BibRef

Batenburg, K.J.[K. Joost], Palenstijn, W.J.[Willem Jan], Balázs, P.[Péter], Sijbers, J.[Jan],
Dynamic angle selection in binary tomography,
CVIU(117), No. 4, April 2013, pp. 306-318.
Elsevier DOI 1303
Binary tomography; Discrete tomography; Angle selection BibRef

Maurin, B., Doignon, C., de Mathelin, M., Gangi, A.,
A fast and automatic stereotactic registration with a single CT-slice,
CVIU(113), No. 8, August 2009, pp. 878-890.
Elsevier DOI 0906
BibRef
Earlier:
Pose Reconstruction with an Uncalibrated Computed Tomography Imaging Device,
CVPR03(I: 455-460).
IEEE DOI 0307
Stereotactic registration; CT scanner imaging model; Line-to-point matching; Computer-assisted radiology BibRef

Quan, E.M., Lalush, D.S.,
Three-Dimensional Imaging Properties of Rotation-Free Square and Hexagonal Micro-CT Systems,
MedImg(29), No. 3, March 2010, pp. 916-923.
IEEE DOI 1003
BibRef

Lu, W., Lu, Y.,
JIGSAW: Joint Inhomogeneity Estimation via Global Segment Assembly for Water-Fat Separation,
MedImg(30), No. 7, July 2011, pp. 1417-1426.
IEEE DOI 1107
BibRef

Roessl, E., Brendel, B., Engel, K.J., Schlomka, J.P., Thran, A., Proksa, R.,
Sensitivity of Photon-Counting Based K-Edge Imaging in X-ray Computed Tomography,
MedImg(30), No. 9, September 2011, pp. 1678-1690.
IEEE DOI 1109
BibRef

Zagorodnov, V.[Vitali], Ciptadi, A.[Arridhana],
Component Analysis Approach to Estimation of Tissue Intensity Distributions of 3D Images,
MedImg(30), No. 3, March 2011, pp. 838-848.
IEEE DOI 1103
BibRef
Earlier: A2, A1 And Add: A2: Chen, C.[Cheng], ICCV09(1765-1770).
IEEE DOI 0909
Model tissue density. BibRef

Klann, E.[Esther],
A Mumford-Shah-Like Method for Limited Data Tomography with an Application to Electron Tomography,
SIIMS(4), No. 4 2011, pp. 1029.
DOI Link 1112
BibRef

Klann, E.[Esther], Ramlau, R.[Ronny],
Regularization Properties of Mumford-Shah-Type Functionals with Perimeter and Norm Constraints for Linear Ill-Posed Problems,
SIIMS(6), No. 1, 2013, pp. 413-436.
DOI Link 1304
Apply to SPECT BibRef

Luo, J.H.[Jian-Hua], Liu, J.H.[Jia-Hai], Li, W.Q.[Wan-Qing], Zhu, Y.M.[Yue-Min], Jiang, R.Y.[Rui-Yao],
Image Reconstruction from Sparse Projections Using S-Transform,
JMIV(43), No. 3, July 2012, pp. 227-239.
WWW Link. 1204
Reduce radiation in CT imaging. BibRef

Persson, M., Bornefalk, H.,
A Framework for Evaluating Threshold Variation Compensation Methods in Photon Counting Spectral CT,
MedImg(31), No. 10, October 2012, pp. 1861-1874.
IEEE DOI 1210
BibRef
And: Erratum: MedImg(39), No. 2, February 2020, pp. 544-544.
IEEE DOI 2002
Calibration, Computed tomography, Image reconstruction, Image segmentation BibRef

Yveborg, M., Persson, M., Bornefalk, H.,
Optimal Frequency-Based Weighting for Spectral X-Ray Projection Imaging,
MedImg(34), No. 3, March 2015, pp. 779-787.
IEEE DOI 1503
computerised tomography BibRef

Bornefalk, H., Persson, M., Danielsson, M.,
Allowable Forward Model Misspecification for Accurate Basis Decomposition in a Silicon Detector Based Spectral CT,
MedImg(34), No. 3, March 2015, pp. 788-795.
IEEE DOI 1503
computerised tomography BibRef

Yveborg, M., Danielsson, M., Bornefalk, H.,
Theoretical Comparison of a Dual Energy System and Photon Counting Silicon Detector Used for Material Quantification in Spectral CT,
MedImg(34), No. 3, March 2015, pp. 796-806.
IEEE DOI 1503
computerised tomography BibRef

Gopinath, A., Xu, G., Ress, D., Oktem, O., Subramaniam, S., Bajaj, C.,
Shape-Based Regularization of Electron Tomographic Reconstruction,
MedImg(31), No. 12, December 2012, pp. 2241-2252.
IEEE DOI 1212
BibRef

Wei, H., Soleimani, M.,
Electromagnetic Tomography for Medical and Industrial Applications: Challenges and Opportunities,
PIEEE(100), No. 3, March 2013, pp. 559-565.
IEEE DOI 1303
Point of View article. BibRef

Wernersson, E.L.G.[Erik L. G.], Boone, M.N.[Matthieu N.], van den Bulcke, J.[Jan], van Hoorebeke, L.[Luc], Hendriks, C.L.L.[Cris L. Luengo],
Postprocessing method for reducing phase effects in reconstructed microcomputed-tomography data,
JOSA-A(30), No. 3, March 2013, pp. 455-461.
WWW Link. 1303
BibRef

van Aarle, W., Batenburg, K.J., van Gompel, G., van de Casteele, E., Sijbers, J.,
Super-Resolution for Computed Tomography Based on Discrete Tomography,
IP(23), No. 3, March 2014, pp. 1181-1193.
IEEE DOI 1403
bone BibRef

Kaganovsky, Y.[Yan], Li, D.[Daheng], Holmgren, A.[Andrew], Jeon, H.[Hyung_Ju], MacCabe, K.P.[Kenneth P.], Politte, D.G.[David G.], O'Sullivan, J.A.[Joseph A.], Carin, L.[Lawrence], Brady, D.J.[David J.],
Compressed sampling strategies for tomography,
JOSA-A(31), No. 7, July 2014, pp. 1369-1394.
DOI Link 1407
Tomography BibRef

Lukic, T.[Tibor], Nagy, B.[Benedek],
Deterministic discrete tomography reconstruction by energy minimization method on the triangular grid,
PRL(49), No. 1, 2014, pp. 11-16.
Elsevier DOI 1410
BibRef
Earlier:
Energy-Minimization Based Discrete Tomography Reconstruction Method for Images on Triangular Grid,
IWCIA12(274-284).
Springer DOI 1211
Discrete tomography
See also Distances with neighbourhood sequences in cubic and triangular grids. BibRef

Nagy, B.[Benedek], Moisi, E.V.[Elisa Valentina],
Binary Tomography on the Triangular Grid with 3 Alternative Directions: A Genetic Approach,
ICPR14(1079-1084)
IEEE DOI 1412
Image color analysis BibRef

Lukic, T.[Tibor], Marceta, M.[Marina],
Gradient and Graph Cuts Based Method for Multi-level Discrete Tomography,
IWCIA17(322-333).
Springer DOI 1706
BibRef

Faridani, A.[Adel], Hass, R.[Ryan],
On Numerical Analysis of View-Dependent Derivatives in Computed Tomography,
JMIV(52), No. 3, July 2015, pp. 356-368.
WWW Link. 1506
BibRef

Lee, J.S.[Jhih-Shian], Chen, J.C.[Jyh-Cheng],
A Single Scatter Model for X-ray CT Energy Spectrum Estimation and Polychromatic Reconstruction,
MedImg(34), No. 6, June 2015, pp. 1403-1413.
IEEE DOI 1506
Compton effect BibRef

Samelsohn, G.[Gregory],
Transmission tomography of forward-scattering structures,
JOSA-A(33), No. 6, June 2016, pp. 1181-1192.
DOI Link 1606
Inverse scattering; Forward scattering; Tomographic imaging BibRef

Fitschen, J.H.[Jan Henrik], Ma, J.W.[Jian-Wei], Schuff, S.[Sebastian],
Removal of curtaining effects by a variational model with directional forward differences,
CVIU(155), No. 1, 2017, pp. 24-32.
Elsevier DOI 1702
Focused ion beam (FIB) tomography. BibRef

Shamul, N., Joskowicz, L.,
Automatic Change Detection in Sparse Repeat CT Scanning,
MedImg(39), No. 1, January 2020, pp. 48-61.
IEEE DOI 2001
Computed tomography, Image reconstruction, Optimization, Greedy algorithms, Change detection algorithms, sparse CT scanning BibRef

Medan, G., Joskowicz, L.,
Reduced-Dose Imageless Needle and Patient Tracking in Interventional CT Procedures,
MedImg(36), No. 12, December 2017, pp. 2449-2456.
IEEE DOI 1712
Computed tomography, Image reconstruction, Needles, reduced dose CT scanning BibRef

Schmidt, T.G., Barber, R.F., Sidky, E.Y.,
A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data,
MedImg(36), No. 9, September 2017, pp. 1808-1819.
IEEE DOI 1709
computerised tomography, energy-window spectra, photon-counting detector, ring artifact reduction, Iterative reconstruction, material decomposition, BibRef

Bappy, D.M., Jeon, I.[Insu],
Modified simultaneous iterative reconstruction technique for fast, high-quality CT reconstruction,
IET-IPR(11), No. 9, September 2017, pp. 701-708.
DOI Link 1709
BibRef

Simonov, N., Kim, B.R., Lee, K.J., Jeon, S.I., Son, S.H.,
Advanced Fast 3-D Electromagnetic Solver for Microwave Tomography Imaging,
MedImg(36), No. 10, October 2017, pp. 2160-2170.
IEEE DOI 1710
cancer, image reconstruction, inverse problems, medical microwave imaging, permittivity, phantoms, tomography, advanced fast 3D electromagnetic solver, BibRef

Ramos, T., Jorgensen, J.S., Andreasen, J.W.,
Automated angular and translational tomographic alignment and application to phase-contrast imaging,
JOSA-A(34), No. 10, October 2017, pp. 1830-1843.
DOI Link 1710
Tomography, X-ray imaging, Synchrotron radiation BibRef

Rigaud, G.[Gaël],
Compton Scattering Tomography: Feature Reconstruction and Rotation-Free Modality,
SIIMS(10), No. 4, 2017, pp. 2217-2249.
DOI Link 1801
BibRef

Pujadas, E.R.[Esmeralda Ruiz], Piella, G.[Gemma], Kjer, H.M.[Hans Martin], González Ballester, M.A.[Miguel Angel],
Random walks with statistical shape prior for cochlea and inner ear segmentation in micro-CT images,
MVA(29), No. 3, April 2018, pp. 405-414.
Springer DOI 1804
BibRef
Earlier: A1, A3, A2, A4:
Statistical Shape Model with Random Walks for Inner Ear Segmentation,
SeSAME16(92-102).
Springer DOI 1703
BibRef

Kallel, F.[Fathi], Sahnoun, M.[Mouna], Ben Hamida, A.[Ahmed], Chtourou, K.[Khalil],
CT scan contrast enhancement using singular value decomposition and adaptive gamma correction,
SIViP(12), No. 5, July 2018, pp. 905-913.
Springer DOI 1806
BibRef

Liu, Z., Chatzidakis, S., Scaglione, J.M., Liao, C., Yang, H., Hayward, J.P.,
Muon Tracing and Image Reconstruction Algorithms for Cosmic Ray Muon Computed Tomography,
IP(28), No. 1, January 2019, pp. 426-435.
IEEE DOI 1810
Mesons, Scattering, Computed tomography, Image reconstruction, X-rays, Fuels, Dry storage cask, muon computed tomography, algebraic reconstruction technique BibRef

Xu, H.Y.[Hui-Ying], Xin, R.[Rui], Zhao, Y.F.[Yu-Fei], Jin, X.M.[Xian-Mei],
Image quality study of CT imaging examination in children with childhood tumors under ultrasound-guided puncture,
JVCIR(65), 2019, pp. 102630.
Elsevier DOI 1912
Ultrasound, Puncture, Childhood tumor, CT imaging, Image quality BibRef

Gupta, A.[Abhishek],
Challenges for computer aided diagnostics using X-ray and tomographic reconstruction images in craniofacial applications,
IJCVR(10), No. 4, 2020, pp. 360-371.
DOI Link 2007
BibRef

Liu, G.D.[Guang-Dong], Zhang, K.[Kaiyin],
A modified contrast source inversion method for microwave tomographic imaging of Debye dispersive media,
IJIST(32), No. 6, 2022, pp. 2281-2291.
DOI Link 2212
contrast source inversion, Debye dispersive media, electromagnetic inverse scattering BibRef

Viermetz, M.[Manuel], Gustschin, N.[Nikolai], Schmid, C.[Clemens], Haeusele, J.[Jakob], Gleich, B.[Bernhard], Renger, B.[Bernhard], Koehler, T.[Thomas], Pfeiffer, F.[Franz],
Initial Characterization of Dark-Field CT on a Clinical Gantry,
MedImg(42), No. 4, April 2023, pp. 1035-1045.
IEEE DOI 2304
Computed tomography, Gratings, X-ray imaging, Geometry, Vibrations, Scattering, Optical interferometry, Computed tomography, X-ray imaging BibRef


Fang, C.W.[Chao-Wei], Wang, L.[Liang], Zhang, D.W.[Ding-Wen], Xu, J.[Jun], Yuan, Y.X.[Yi-Xuan], Han, J.W.[Jun-Wei],
Incremental Cross-view Mutual Distillation for Self-supervised Medical CT Synthesis,
CVPR22(20645-20654)
IEEE DOI 2210
Interpolation, Image resolution, Computed tomography, Computational modeling, Synthesizers, Pipelines, Low-level vision BibRef

Yang, Z.D.[Zhi-Dong], Zhang, F.[Fa], Han, R.[Renmin],
Self-Supervised Cryo-Electron Tomography Volumetric Image Restoration from Single Noisy Volume with Sparsity Constraint,
ICCV21(4036-4045)
IEEE DOI 2203
Training, Instruments, Noise reduction, Data visualization, Tomography, Image restoration, Medical, biological, Vision applications and systems BibRef

Abujbara, K.[Khaled], Idoughi, R.[Ramzi], Heidrich, W.[Wolfgang],
Non-Linear Anisotropic Diffusion for Memory-Efficient Computed Tomography Super-Resolution Reconstruction,
3DV21(175-185)
IEEE DOI 2201
Anisotropic magnetoresistance, Computed tomography, Superresolution, Noise reduction, Filtering algorithms, Regularization by Denoising BibRef

Tao, H., Wang, Z., Gao, Y., Wang, Y., Khan, L.,
Adaptive Multi-Region Network For Medical Image Analysis,
ICIP20(71-75)
IEEE DOI 2011
Lesions, Measurement, Medical diagnostic imaging, Computed tomography, Adaptive systems, Radiology, automated diagnosis BibRef

Yan, K.[Ke], Peng, Y.F.[Yi-Fan], Sandfort, V.[Veit], Bagheri, M.[Mohammadhadi], Lu, Z.Y.[Zhi-Yong], Summers, R.M.[Ronald M.],
Holistic and Comprehensive Annotation of Clinically Significant Findings on Diverse CT Images: Learning From Radiology Reports and Label Ontology,
CVPR19(8515-8524).
IEEE DOI 2002
BibRef

Guo, Y.[Yan], Rieger, B.[Bernd],
Parameter Selection for Regularized Electron Tomography Without a Reference Image,
SCIA19(452-464).
Springer DOI 1906
BibRef

Yu, H.B., Ho, H.,
Methods and apparatus for tracking internal structures in soft objects: A phantom-based study,
IVCNZ17(1-6)
IEEE DOI 1902
finite element analysis, medical image processing, phantoms, stereo image processing, Force BibRef

Guo, J.L.[Jia-Liang], Zhou, B.[Bo], Zeng, X.R.[Xiang-Rui], Freyberg, Z.[Zachary], Xu, M.[Min],
Model Compression for Faster Structural Separation of Macromolecules Captured by Cellular Electron Cryo-Tomography,
ICIAR18(144-152).
Springer DOI 1807
BibRef

Luu, M.H.[Manh Ha], Boulkhrif, H.[Hassan], Moelker, A.[Adriaan], van Walsum, T.[Theo],
Registration Evaluation by De-enhancing CT Images,
WBIR18(83-93).
Springer DOI 1806
BibRef

Rodriguez, A.L.[Antonio L.], Taddei, P.[Pierluigi], Sequeira, V.[Vitor],
Multimodal Calibration of Portable X-Ray Capture Systems for 3D Reconstruction,
3DV14(345-352)
IEEE DOI 1503
Calibration BibRef

Cogranne, R.[Remi], Retraint, F.[Florent],
A new tomography model for almost optimal detection of anomalies,
ICIP13(1461-1465)
IEEE DOI 1402
Background subtraction BibRef

Bai, F., Pizurica, A., van Loocke, S., Franchois, A., de Zutter, D., Philips, W.,
Quantitative microwave tomography from sparse measurements using a robust huber regularizer,
ICIP12(2073-2076).
IEEE DOI 1302
BibRef

Plumat, J., Macq, B., Kohli, P.,
Higher-order density consistency potentials for Discrete Tomography,
ICIP12(2065-2068).
IEEE DOI 1302
BibRef

Svensson, L.[Lennart], Brun, A.[Anders], Nyström, I.[Ingela], Sintorn, I.M.[Ida-Maria],
Registration Parameter Spaces for Molecular Electron Tomography Images,
CIAP11(I: 403-412).
Springer DOI 1109
BibRef

Fang, Y.[Yi], Sun, M.T.[Meng-Tian], Vishwanathan, S.V.N., Ramani, K.[Karthik],
sLLE: Spherical locally linear embedding with applications to tomography,
CVPR11(1129-1136).
IEEE DOI 1106
BibRef

Shimizu, A.[Akinobu], Nakagomi, K.[Keita], Narihira, T.[Takuya], Kobatake, H.[Hidefumi], Nawano, S.[Shigeru], Shinozaki, K.[Kenji], Ishizu, K.[Koich], Togashi, K.[Kaori],
Automated Segmentation of 3D CT Images Based on Statistical Atlas and Graph Cuts,
MCV10(214-223).
Springer DOI 1009
BibRef

Criminisi, A.[Antonio], Shotton, J.D.J.[Jamie D.J.], Robertson, D.[Duncan], Konukoglu, E.[Ender],
Regression Forests for Efficient Anatomy Detection and Localization in CT Studies,
MCV10(106-117).
Springer DOI 1009
BibRef

Hishida, H.[Hiroyuki], Michikawa, T.[Takashi], Ohtake, Y.[Yutaka], Suzuki, H.[Hiromasa], Oota, S.[Satoshi],
CT Image Segmentation Using Structural Analysis,
ISVC10(III: 39-48).
Springer DOI 1011
BibRef

Kang, D.G.[Dong-Goo], Sung, Y.H.[Young-Hun], Kim, S.S.[Sung-Su], Lee, S.D.[Seong-Deok], Kim, C.Y.[Chang-Yeong],
Multiple object decomposition based on independent component analysis of multi-energy x-ray projections,
ICIP09(4173-4176).
IEEE DOI 0911
BibRef

Zhao, L.[Liang], Li, C.H.[Chang-Hua], Chen, D.F.[Deng-Feng], Dang, F.N.[Fa-Ning],
Concrete CT Image Segmentation Using Modified Metropolis Dynamics,
CISP09(1-4).
IEEE DOI 0910
BibRef

Kazemi, K.[Kamran], Ghadimi, S.[Sona], Lyaghat, A.[Alireza], Tarighati, A.[Alla], Golshaeyan, N.[Narjes], Abrishami-Moghaddam, H.[Hamid], Grebe, R.[Reinhard], Gondary-Jouet, C.[Catherine], Wallois, F.[Fabrice],
Automatic Fontanel Extraction from Newborns' CT Images Using Variational Level Set,
CAIP09(639-646).
Springer DOI 0909
BibRef

Let, S.N.[Sang N.], Lee, M.K.[Mei Kay], Banu, S.[Shamima], Fang, A.C.[Anthony C.],
Volumetric reconstruction from multi-energy single-view radiography,
CVPR08(1-8).
IEEE DOI 0806
BibRef

Hugueny, S.[Samuel], Rousson, M.[Mikaël],
Hierarchical Detection of Multiple Organs Using Boosted Features,
CAIP07(317-325).
Springer DOI 0708
BibRef

Španel, M.[Michal], Kršek, P.[Premysl], Švub, M.[Miroslav], Štancl, V.[Vít],
Tetrahedral Meshing of Volumetric Medical Images Respecting Image Edges,
CAIP11(I: 161-169).
Springer DOI 1109
BibRef

Španel, M.[Michal], Kršek, P.[Premysl], Švub, M.[Miroslav], Štancl, V.[Vít], Šiler, O.[Ondrej],
Delaunay-Based Vector Segmentation of Volumetric Medical Images,
CAIP07(261-269).
Springer DOI 0708
BibRef

Semler, L.[Lindsay], Dettori, L.[Lucia],
A Comparison of Wavelet-Based and Ridgelet-Based Texture Classification of Tissues in Computed Tomography,
VISAPP06(240-250).
Springer DOI 0711
BibRef
And:
Curvelet-Based Texture Classification of Tissues in Computed Tomography,
ICIP06(2165-2168).
IEEE DOI 0610
BibRef

Dedual, N., Johnson, B., Chen, G.,
Visualization of 4D Computed Tomography Datasets,
Southwest06(120-123).
IEEE DOI 0603
BibRef

Zhang, X.Q.[Xiao-Qun], Froment, J.[Jacques],
Constrained Total Variation Minimization and Application in Computerized Tomography,
EMMCVPR05(456-472).
Springer DOI 0601
BibRef

Ding, F.[Feng], Li, H.[Hao], Cheng, Y.[Yuan], Leow, W.K.[Wee Kheng],
Medical volume image summarization,
WACV09(1-6).
IEEE DOI 0912
BibRef

Ding, F.[Feng], Leow, W.K.[Wee Kheng], Wang, S.C.[Shih-Chang],
Segmentation of 3D CT Volume Images Using a Single 2D Atlas,
CVBIA05(459-468).
Springer DOI 0601
BibRef

Boverman, G., Miller, E.,
Adjoint field methods for non-linear tomographic medical imaging problems,
ICIP02(II: 633-636).
IEEE DOI 0210
BibRef

Robini, M.C.[Marc C.], Magnin, I.E.[Isabelle E.],
3-D reconstruction from a Few Radiographs using the Metropolis Dynamics with Annealing,
ICIP99(III:876-880).
IEEE DOI BibRef 9900

Kwon, S.M.[Sung-Min], Kim, J.K.[Jin Kook], Ra, J.B.[Jong Beom],
A Block-Based Volume Rendering Scheme for the Spine Biopsy Simulator,
ICIP99(II:187-191).
IEEE DOI BibRef 9900

Glasbey, C.A., Robinson, C.D., Young, M.J.,
Segmentation of X-ray CT images using stochastic templates,
CIAP99(746-751).
IEEE DOI 9909
BibRef

Brown, M.S., McNitt-Gray, M.F., Goldin, J.G., and Aberle, D.R.,
An Extensible Knowledge-Based Architecture for Segmenting Computed Tomography Images,
ICIP97(III: 516-519).
IEEE DOI BibRef 9700

Isernia, T., Pascazio, V., and Pierri, R.,
Tomographic Imaging via Non Linear Estimation: A Bilinear Approach,
ICIP97(I: 480-483).
IEEE DOI BibRef 9700

Sankar, G.[Gomathi], and Gupta, S.,
A New Technique for Region of Interest Tomographic Image Reconstruction and a Comparison of the Related Algorithms,
ICIP97(I: 141-144).
IEEE DOI 9710
BibRef

Karron, D.B., Cox, J.,
The Spiderweb Algorithm for Extracting 3D Objects from Volume Data,
CVRMed95(XX-YY) BibRef 9500

Hamitouche, C., Roux, C., Coatrieux, J.L.,
Design of New Surface Detection Operators in the Case of an Anisotropic Sampling of 3D Volume Data,
CVRMed95(XX-YY) BibRef 9500

Kerfoot, I.B., Bresler, Y.,
Theoretical analysis of a multiscale algorithm for the direct segmentation of tomographic images,
ICIP94(II: 177-181).
IEEE DOI 9411
BibRef

Jaffe, J.S., Palowitch, A.W.,
Determining underwater optical characteristics using serial section tomography,
ICIP94(II: 173-176).
IEEE DOI 9411
BibRef

Neumann, H., Ottenberg, K., Stiehl, H.S.,
Finding and describing local structure in discrete two-dimensional computed tomograms,
ICPR92(III:408-412).
IEEE DOI 9208
BibRef

Chapter on Medical Applications, CAT, MRI, Ultrasound, Heart Models, Brain Models continues in
Tomographic Images, CAT, CT, Overviews, Surveys, Datasets .


Last update:Mar 16, 2024 at 20:36:19